Descriere
Genius-15 Multi-Parameter Monitor
Medical Equipment Patient Monitor Genius-15 Multi-Parameter Monitor

Applications

Genius-15 multi-parameter monitor is especially designed for anaesthesia use. It can monitor standard parameters of ECG, SpO2, RESP, NIBP, TEMP and PR. With.a CSM module, it can also monitor parameters of CSI, EEG, EMG and BS% with alarm.

Features
1. Genius-15 multi-parameter monitor comes with a 15" high resolution color LCD screen.
2. It uses a built-in printer which allows printing of values and curves if needed.
3. It has a portable handset with wireless connection to main unit for data processing.
4. The multi-parameter monitor adopts digital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
5. It offers optimized NIBP measurement modes for adult, neonatal and pediatric patients.
6. It allows automatic analysis of 20 arrhythmia waveforms.
7. The multi-parameter monitor can store up to 400 groups of data as well as 24 hour ECG waveforms.
8. It provides protection against interference from defibrillator and electrosurgical generator.
9. Automatic and manual analysis is available for S-T segment.

Specifications of Genius-15 Multi-Parameter Monitor

CSM EEG sensitivity 400μV
Noise level <2μVp-p, <0.4μV RMS, 1~250Hz
CMR >140dB
Input impedance >50Mohm
Sample rate 2000 samples/sec. (14 bits equivalent)
CSI and update 0-100. Filter 6-42Hz, 1sec. update
EMG 0-100 logarithmic. Filter 75-85Hz, 1 sec. update
BS% 0-100%. Filter 2-42Hz, 1 sec. update
Wireless range Up to 10 meters

ECG Heart rate display range 15bpm ~ 350bpm
Heart rate display accuracy 1% or 2bpm, whichever is greater
Sweeping speed 12.5mm/s, 25mm/s, 50mm/s
Sensitivity selection ×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
CMRR ≥ 89dB

RESP Measuring range 0rpm~120rpm
Accuracy 5% or 2 rpm
Alarm limits setting range 0rpm~120rpm

TEMP Measuring range 25.0℃ ~45.0℃
Measuring accuracy 0.2℃
Responding time ≤150s

NIBP Measuring method Oscillometric Technique
Measuring range 0mmHg~300mmHg
Accuracy Maximal mean difference 5 mmHg
Maximal standard deviation 8 mmHg
Measurement range Adult SYS 40 ~ 255 mmHg
MAP 20 ~ 215 mmHg
DIA 10 ~ 195 mmHg
Pediatric patient SYS 40 ~ 200 mmHg
MAP 20 ~ 165 mmHg
DIA 10 ~ 150 mmHg
Neonate SYS 40 ~ 135 mmHg
MAP 20 ~ 110 mmHg
DIA 10 ~ 95 mmHg

SpO2 Measuring range 35%~100%
Low perfusion capability 0.4%~5%
Accuracy Not greater than 3% for SpO2range from 70% to 100%

PR Measuring range 30bpm~240bpm
Measuring accuracy 2bpm or 2%, whichever is greater

General Power supply 100~240VAC, 50/60Hz

Rechargeable Li-ion battery 12V 2.3Ah
Display mode 15 inches TFT color LCD
Alarming mode Audible and visible alarm